Call 08046033631 82% Response Rate

our range

CO Sensor

Wholesale Distributor of a wide range of products which include honeywell hcmd5b1000-mod carbon monoxide detector, greystone co (carbon monoxide) sensor cmd5b1000, honeywell hcmd5b1000 carbon monoxide detector and honeywell wall mount co sensor.
  • Honeywell HCMD5B1000-MOD Carbon Monoxide Detector
  • Honeywell HCMD5B1000-MOD Carbon Monoxide Detector
  • Honeywell HCMD5B1000-MOD Carbon Monoxide Detector
Honeywell HCMD5B1000-MOD Carbon Monoxide Detector

Honeywell HCMD5B1000-MOD Carbon Monoxide Detector

Rs 25,171  / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

ModelHCMD5B1000-MOD
BrandHoneywell
Response Time<35 seconds for 90% step change
Accuracy+-5 PPM or 5% of reading (whichever is greater)
External Dimensions71 x 104 x 46mm
Sensor Agency ApprovalsSensor is UL Recognized Component for ANSI/UL-2034
Enclosure RatingsABS - UL94-V - IP65 (NEMA 4X)
Sensor TypeElectrochemical Carbon Monoxide Detector
Life Expectancy5-7 years in air
Sample MethodDiffusion
Measurement Range0-500 PPM
Wiring ConnectionsScrew terminal block (14 to 22 AWG)
OptionsModbus Communications
Typical Coverage Area700 m square (7500 ft Square) or 15 m (50 ft square) radius
Stability<5% signal loss/year
Operating Conditions-20 Deg.C to 50 Deg.C 15 to 95% RH
Accuracy rated0Deg.C to 50Deg.C

The HCMD5B1 Series carbon monoxide detector uses a superior electrochemical sensing element with state-of-the-art digital linearization circuitry in a compact wall mount ABS enclosure to detect CO levels. It provides a linear analog signal output of 4-20 mA (Loop-powered with 24 Vdc) signal or optional Modbus communications. An optional alarm relay are available.

 

APPLICATIONS
The HCMD5B1 series carbon monoxide detector is designed for use with electronic controllers in domestic or commercial heating and cooling systems

 

FEATURES

• Electrochemical sensing element
• 0-300 PPM (Analog) or 0-500 PPM (Modbus)
• Loop-powered 4-20 mA output
• Optional adjustable alarm relay
• Optional Modbus communications
• Compact ABS enclosure

View Complete details

get quote request a call back
  • GreyStone CO (Carbon Monoxide) Sensor CMD5B1000
  • GreyStone CO (Carbon Monoxide) Sensor CMD5B1000
  • GreyStone CO (Carbon Monoxide) Sensor CMD5B1000
GreyStone CO (Carbon Monoxide) Sensor CMD5B1000

GreyStone CO (Carbon Monoxide) Sensor CMD5B1000

Rs 7,000  / PieceGet Best Price

Product Brochure

Mounting TypeWall Mount
BrandGreyStone
ModelCMD5B1000
Accuracy5%
Humidity RangeNA
Measuring Range0-250 PPM
Model NumberCMDB1000
Power Supply24V
We have Greystone Wall Mount CO Sensor, Model: CMD5B1000 in stock. Please contact us for special prices

Additional Information:

  • Delivery Time: Ready Stock
  • Packaging Details: 01 No Box

View Complete details

get quote request a call back
  • Honeywell HCMD5B1000 Carbon Monoxide Detector
  • Honeywell HCMD5B1000 Carbon Monoxide Detector
Honeywell HCMD5B1000 Carbon Monoxide Detector

Honeywell HCMD5B1000 Carbon Monoxide Detector

Rs 18,879  / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

ModelHCMD5B1000
BrandHoneywell
Response Time<35 seconds for 90% step change
Accuracy+-5 PPM or 5% of reading (whichever is greater)
Sensor TypeElectrochemical Carbon Monoxide Detector
Accuracy rated0 Deg.C to 50 Deg.C
Enclosure RatingsABS -UL94-V- IP65 (NEMA 4X)
Sample MethodDiffusion
Output Drive at Capability550 ohms max. at 24 Vac/dc
Life Expectancy5-7 years in air
Power Supply24 Vdc +- 20% or 24 Vac +- 10%
Consumption50 mA max
Typical Coverage Area700 m square (7500 ft square) or 15 m (50 ft square) radius
Relay ContactsForm C contact ( N.O. and N.C.) 5 amps at 250 Vac
Relay OutputForm C
External Dimensions71 x 104 x 46mm
Measurement Range0-300 PPM
Sensor Agency ApprovalsSensor is UL Recognized Component for ANSI/UL-2034
Output Signal4-20 mA sourcing
Wiring ConnectionsScrew terminal block (14 to 22 AWG)
Operating Conditions-20 Deg.C to 50 Deg.C 15 to 95% RH
Relay Hysteresis3% or 9 ppm
Relay Trip Point25
Stability<5 signal loss/year

The HCMD5B1 Series carbon monoxide detector uses a superior electrochemical sensing element with state-of-the-art digital linearization circuitry in a compact wall mount ABS enclosure to detect CO levels. It provides a linear analog signal output of 4-20 mA (Loop-powered with 24 Vdc) signal or optional Modbus communications. An optional alarm relay are available.

 

APPLICATIONS
The HCMD5B1 series carbon monoxide detector is designed for use with electronic controllers in domestic or commercial heating and cooling systems

 

FEATURES

• Electrochemical sensing element
• 0-300 PPM (Analog) or 0-500 PPM (Modbus)
• Loop-powered 4-20 mA output
• Optional adjustable alarm relay
• Optional Modbus communications
• Compact ABS enclosure

View Complete details

get quote request a call back
  • Honeywell Wall Mount CO Sensor
  • Honeywell Wall Mount CO Sensor
  • Honeywell Wall Mount CO Sensor
Honeywell Wall Mount CO Sensor

Honeywell Wall Mount CO Sensor

Rs 1,500  / PieceGet Best Price

Minimum Order Quantity: 01 Piece

BrandHoneywell
ColorWhite
MaterialABS
HVAC applicationsPt1000
Probe Length300 mm
FlangeAdjustable
CO Sensor

We have a complete stock of Honeywell Wall Mount CO sensor with & without display with Analog Output.

Additional Information:

  • Delivery Time: Ready Stock
  • Packaging Details: 01 No Box

View Complete details

get quote request a call back

EXPLORE MORE CATEGORIES